| Inputs: | Adjustable for all sensors | |
| | Functions: PAXC: 2 separate up/down counters, difference, total, position display for rotary encoders with 2 channels x1, x2, x4, | |
| | PAXR: Tachometer | |
| Display capacity: | PAXC: 6-digit, 14 mm high red LED, | |
| | PAXR: 5-digit, 14 mm high red LED | |
| Indicators: | SP1-4: Output 1-4 is active | |
| | PAXC: A, B, C: counter A, B, C | |
| | PAXR: | r: Tachometer |
| | | H: maximum value |
| | | L: Minimum value |
| Counter (PAXC only): | 2 independent and scalable internal 9-digit counters. A third counter capable of displaying the total or difference | |
| Tachometer (PAXR only): | 1 scalable tachometer with continuous period measurement | |
| | | |
| Procedure: | Simple operation using 5 buttons | |
| Projection: | Fast and menu-driven configuration with 5 buttons | |
| User inputs: | 3 programmable inputs are available. | |
| | (Reset total/display/min/max value, programming lock) | |
| Power supply: | 11 to 36 V dc, 14 W or 24 V ac ±10%. 15 VA | |
| Sensor power supply: | 12 V dc ±10 %, max. 100 mA | |
| Output option cards: | Very easy to upgrade | |
| . | 1. 2 x relay changeover contact 5 A at 120 / 230 V ac | |
| | 2. 4 x N/O relays 3 A at 250 V ac | |
| Housing: | Shockproof plastic housing | |
| | IP65 (front) | |
| | Dimensions (H x W x D): 48 x 96 x 105 mm | |
| Connection: | Secure terminal strips | |
| Ambient temperature: | Operation: 0°C to +50°C | |
| | Storage: -40°C to +85°C | |